Technical parameter |
|
Rated power |
7KW |
Charging gun |
Single |
Display mode |
4.3-inch display (without touch) |
Charging mode |
RFID card, optional scanning code |
Charging mode |
autofill |
Installation mode |
Wall hanging, column type |
ammeter |
Integrated onboard electric meter |
Lightning protection |
Integrated on-board lightning protection |
Input |
|
Input voltage (V) |
220Vac±15% |
Input phase current (A) |
32A |
Ac input Frequency (HZ) |
45~55 |
Output |
|
Output voltage range (V) |
220Vac±15% |
Rated output phase current (A) |
32A |
PWM duty cycle |
53.3% |
Maximum output power (kW) |
7kW |
Gun length (m) |
3.5m |
Protective characteristic |
|
Output short-circuit protection |
No output after protection, unrecoverable (manual recovery required) |
Output overcurrent protection |
No output after protection, unrecoverable (manual recovery required) |
Output overvoltage protection |
No output after protection, can be restored (no manual recovery) |
Input undervoltage protection |
Reduced power after protection, recoverable (no manual recovery required) |
PWM exception protection |
No output after protection, unrecoverable (manual recovery required) |
Scram protection |
No output after protection, unrecoverable (manual recovery required) |
Ac leakage protection |
No output after protection, unrecoverable (manual recovery required) |
Connection exception protection |
After protection, there is no output and can be restored |
Safety characteristic |
|
Withstand voltage test voltage (input-chassis) |
2000Vac 1min 10mA |
Withstand voltage test voltage (output - chassis) |
2000Vac 1min 10mA |
Input insulation resistance to chassis (DC500V) |
≥10MΩ(Atmospheric relative humidity 90%, no condensation) |
Output insulation resistance to chassis (DC500V) |
≥10MΩ (Atmospheric relative humidity 90%, no condensation) |